A system for connecting bars used when the building element is very long and it is necessary to connect bars due to their limited size (12 m maximum). The normal joint procedures are as follows:
- By means of welding: welding bars.
- Mechanical: attaching bell-sockets to the two bars.
- Overlap: overlapping parts of the bars to increase length. This is normal in small building works.